When we put a mechanical watch on a timing machine (timegrapher), these are the main values we look at. They say a great deal about the condition and quality of the movement.

Power reserve

The power reserve tells you how long a fully wound watch runs without being wound again. Many classic movements reach around 40 hours, some modern movements 70 hours or more. If the power reserve becomes noticeably shorter, this can be a sign that the watch needs a service.

Frequency

The frequency tells you how often the balance oscillates. It is given in beats (semi-oscillations) per hour, vph, or in hertz. Common values are 21,600 vph (3 Hz) and 28,800 vph (4 Hz). A higher frequency can make the rate more stable, and the seconds hand moves more smoothly.

Amplitude

The amplitude is the angle through which the balance swings from its rest position, measured in degrees. A healthy, fully wound watch usually reaches well over 250 degrees. A low amplitude often points to aged oils, dirt or a weak mainspring.

Beat error

The beat error shows how evenly the balance swings to the left and to the right, measured in milliseconds. Ideally it is close to zero. A large beat error can usually be corrected by the watchmaker.

And the rate?

All these values influence the actual rate – how many seconds a day the watch gains or loses. Because a watch can run differently in different positions, it is measured and regulated in several positions.